What do you need to know?
[One instrument, many answers]
The latest labour-saving technique: contact-free ID
tags load the instrument with all measuring point
data and also save the latest measuring results. Aeri-
als for RF transponders are built into the Logger
and Expert versions of the A30.
Speed data are necessary for condition evaluation,
and monitoring the machine temperature often sup-
plies valuable information. A30 uses temperature
probes for solids and liquids. Speed is measured by
contact, or optically from a safe distance.
Special transducers for shock pulses and vibration
assure accurate measurements. On measuring points
that are unaccessible during normal operation, the
transducers are permanently installed and con-
nected to measuring terminals.
Condition monitoring is a money saver and in many cases
a necessary safety precaution. The aim is to detect devel-
oping faults before they become a problem. This becomes
ever more important as the production pace increases and
unmanned operation is getting more common.
The signals generally used to diagnose machine condition
are shocks and vibrations. There are different ways of
processing these signals. Make a strategic choice and
employ the most cost-efficient method that provides a
correct condition evaluation in a given technical situation.
The A30 offers you all the options. With our EVAM
®
method, you have a powerful tool for vibration spectrum
analysis whenever that is needed.
Measuring ISO vibration severity is an easy way to
detect most machine faults except bearing problems, and
for these you have the SPM method, still unsurpassed in
accuracy and reliability.
The Analyzer A30 has many extra functions. You can
measure rotational and peripheral speed. You can measure
the temperature of solids and liquids. You can record the
readings of dials and meters. You can save written com-
ments to the A30 and attach them to the measurement.
For up to 50 hours, you can make a continuous
recording of shock values, vibration, and temperature or
rpm. You can put memory tags on your measuring points,
loaded with all measuring instructions and the results of
the last measurement.
You get evaluated condition readings, immediately. An
arrow on the display points at a green - yellow - red
condition scale. While still on the spot, you can investigate
the causes of any measuring result in the red or yellow
zone. That saves time and money.