Strona 1 - T TTR31, TTR35

BA229R/09/en/07.0771025405Release 01.02Operating manualThermophant® T TTR31, TTR35Temperature switch

Strona 2 - Brief overview

Operation TTR31, TTR3510 Endress+Hauser4. 2 DC voltage version with valve connectorP01-PTx3xxxx-04-xx-xx-xx-003Fig. 6: Thermophant® T with M 16x1.5 o

Strona 3 - Table of contents

TTR31, TTR35 OperationEndress+Hauser 115.1.1 Navigating in the operating menuT09-TTR31xxx-19-xx-xx-xx-002Fig. 8: Navigating in the operating menuA Fun

Strona 4 - 1 Safety instructions

Operation TTR31, TTR3512 Endress+Hauser5.1.2 Structure of the operating menu for 1x or 2x switch outputsT09-TTR31xxx-19-xx-xx-xx-003Fig. 9: Operating

Strona 5 - 2 Device identification

TTR31, TTR35 OperationEndress+Hauser 135.1.3 Structure of the operating menu for 1x switch output or1x analog output (4 to 20 mA)At devices with analo

Strona 6 - 3 Installation

Operation TTR31, TTR3514 Endress+Hauser5.1.4 Basic settings!Note! The function group 4-20 is only available if the 4 to 20 mA analog output (0>.,)

Strona 7 - 3. 3 Process connection

TTR31, TTR35 OperationEndress+Hauser 155.1.5 Settings for output - 2x switch output• Hysteresis functionThe hysteresis function enables two-point cont

Strona 8 - 8 Endress+Hauser

Operation TTR31, TTR3516 Endress+HauserT09-TTR31xxx-05-xx-xx-xx-001Fig. 11: Switch point functionsa: Hysteresis-functionb: Window-function m Window -

Strona 9 - 4 Wiring

TTR31, TTR35 OperationEndress+Hauser 175.1.6 Settings for output - 1x switch output and 1x analog output (4 to 20 mA)Output 1.Output 2, as optio

Strona 10 - 5 Operation

Operation TTR31, TTR3518 Endress+HauserOutput 1.Output 2, as option.Switch-back point value,M, Switch-back point -50 to 149 °C(-58 to 300

Strona 11 - T09-TTR31xxx-19-xx-xx-xx-002

TTR31, TTR35 OperationEndress+Hauser 19!Note! The function group 4-20 is only available if the 4 to 20 mA analog output (0>.,) is selected in the f

Strona 12

Brief overviewUsing the following short form instructions you can commission your system easily and swiftly:Safety instructions → Page 4ÆInstallation

Strona 13 - 1x analog output (4 to 20 mA)

Operation TTR31, TTR3520 Endress+HauserService functions.(if output 2 available)Simulationoutput 1 or 266/M1(if analog output avail

Strona 14 - 0>.,) is selected in

TTR31, TTR35 OperationEndress+Hauser 215. 2 Operation with PCThe device can be configured with the configuration software ReadWin® 2000 or FieldCare.

Strona 15 -   DESINA 

Maintenance TTR31, TTR3522 Endress+Hauser5.2.2 Hints for the configuration with Readwin® 2000Comprehensive information on the ReadWin ® 2000 configura

Strona 16 - 16 Endress+Hauser

TTR31, TTR35 AccessoriesEndress+Hauser 237 AccessoriesIf ordering accessories, please specify the serial number of the unit! All dimensions in the dra

Strona 17 - Endress+Hauser 17

Accessories TTR31, TTR3524 Endress+Hauser!Note! We recommend to change the O-ring in the same time frame as of all other sealings in yourprocess.7.1.2

Strona 18 - 18 Endress+Hauser

TTR31, TTR35 AccessoriesEndress+Hauser 257.1.3 O-ring for adapter replacementO-ring 15.54 x 2.62 mm (0.61 x 0.1 in), EPDM 70 Shore FDA, order no. 5100

Strona 19

Accessories TTR31, TTR3526 Endress+Hauser7.2 Welding bosses and coupling 7.2.1 Welding boss with sealing taper7.2.2 Collar welding boss7.2.3 Weldin

Strona 20 - 20 Endress+Hauser

TTR31, TTR35 AccessoriesEndress+Hauser 277.2.4 Coupling with sealing taper7.3 Electrical connection7.3.1 Plug-in jack; connecting cableMoveable coupli

Strona 21 - 5. 2 Operation with PC

Accessories TTR31, TTR3528 Endress+Hauser7.4 Configuration kitPVC cable, 4 x 0.34 mm2 (22 AWG) with M12x1 coupling, with LED, elbowed, 316L screw plu

Strona 22 - 6 Maintenance

TTR31, TTR35 Trouble-shootingEndress+Hauser 298 Trouble-shooting8. 1 Errors and warningsIf an error in the device occurs, the colour of the status LE

Strona 23 - 7 Accessories

Endress+Hauser 3TTR31, TTR35Table of contents1 Safety instructions . . . . . . . . . . 41. 1 Designated use . . . . . . . . . . . . . . . . . .

Strona 24 - 24 Endress+Hauser

Trouble-shooting TTR31, TTR3530 Endress+Hauser8. 2 RepairA repair is not planned.8. 3 DisposalPlease pay particular attention to the local disposal

Strona 25 - Endress+Hauser 25

TTR31, TTR35 The most important technical dataEndress+Hauser 318. 4 Software history and compatibility overviewThe release number on the nameplate an

Strona 26 - 26 Endress+Hauser

The most important technical data TTR31, TTR3532 Endress+Hauser9. 2 OutputSwitching capacity• Switch status ON: Ia ≤ 250 mA• Switch status OFF: Ia ≤

Strona 27 - 7.3 Electrical connection

TTR31, TTR35 The most important technical dataEndress+Hauser 33Process pressure limitsMaximum permitted process pressure depending on the insertion le

Strona 28 - 7.4 Configuration kit

The most important technical data TTR31, TTR3534 Endress+HauserPermitted flow velocity depending on the insertion length.a0008065-enFig. 15: Permitted

Strona 30 - 8. 3 Disposal

www.endress.com/worldwide BA229R/09/en/07.07 71025405 CCS/FM6.0+SGML

Strona 31 - 9. 1 Power supply

Safety instructions TTR31, TTR354 Endress+Hauser1 Safety instructions1. 1 Designated useThe Thermophant® T is a temperature switch for monitoring, di

Strona 32 - 9.3.1 Environment

TTR31, TTR35 Device identificationEndress+Hauser 52 Device identification2. 1 NameplateTo identify your device, compare the complete order code and t

Strona 33 - L = insertion length

Installation TTR31, TTR356 Endress+HauserUL listed for Canada and USAThe device was examined by Underwriters Laboratories Inc. (UL) in accordance with

Strona 34 - 34 Endress+Hauser

TTR31, TTR35 InstallationEndress+Hauser 73. 3 Process connectionT09-TTR31xxx-17-xx-xx-en-000Fig. 3: Process connection of the devices"Caution! T

Strona 35

Installation TTR31, TTR358 Endress+Hauser3. 4 Installation instructionsT09-TTR31xxx-11-00-xx-xx-000Fig. 4: Possible installation options for temperat

Strona 36 - CCS/FM6.0+SGML

TTR31, TTR35 WiringEndress+Hauser 94 Wiring4. 1 DC voltage version with M12x1 connectorP01-PTx3xxxx-04-xx-xx-xx-002Fig. 5: Thermophant® T with M12x1