20
STEP 1
Install a jam nut and rod joint end onto each end of
the hydraulic cylinder connecting link. Leave jam nuts
loose.
STEP 2
Install the connecting link flat bracket onto the
connecting link angle bracket using two 10-24 x 1/2
socket head bolts.
STEP 3
Install the angle/flat bracket assembly onto the
connecting link using a spacer and shoulder bolt.
Leave shoulder bolt 1/4 turn loose.
STEP 4
Select the two 10-24 screws, rotary potentiometer,
O-ring and angle sensor.
Install the O-ring onto the rotary potentiometer. Align
and install the rotary potentiometer onto the angle
sensor.
RD04H649
RD04F147
RD04H650
RD04H653
1. O-RING
1
Komentarze do niniejszej Instrukcji